Sr.No |
Instrument Name |
Analysis details |
No. of Sample |
. |
Charges (Rs). |
. |
. |
. |
. |
. |
Educational Institution |
R&D/National Lab |
Industry |
1. |
Thermo Gravimetric Analyzer (TGA) |
Material Characterization by thermal analysis (Solid sample) |
Up to 10 S above 10 S |
500 PHr
300 PHr |
1000 PHr
600 PHr |
2000 PHr
1200 PHr |
2. |
Differential Scanning Calorimeter (DSC) |
Material Characterization by thermal analysis (Solid sample) |
Up to 10 S above 10 S |
450 PHr
250 PHr |
900 PHr
500 PHr |
1600 PHr
1000 PHr |
3. |
CHNS/O Analyzer |
Elemental characterization (Quantification) for solid samples |
Up to 5 S CHN Mode Oxygen Mode above 5 S CHN Mode Oxygen Mode |
750 PS
1000 PS
500 PS
600 PS |
1400 PS
1600 PS
1000 PS
1200 PS |
2200 PS
2200 PS
1500 PS
1500 PS |
4. |
TOC Analyzer |
Quantification of total organic, inorganic carbon for solid & liquid sample |
TC/ TIC - Liquid TOC – Liquid TC/TIC – Solid TOC – Solid Up to 4 S 5 S and above TC/ TIC - Liquid TOC – Liquid TC/TIC – Solid TOC – Solid |
400 PS
400 PS
600 PS
600 PS
250 PS
300 PS
350 PS
400 PS |
600 PS
600 PS
800 PS
800 PS
500 PS
500 PS
700 PS
700 PS |
900 PS
1100 PS
1300 PS
1300 PS
900 PS
1000 PS 1100 PS 1200 PS |
5. |
UV/Visible/NIR Spectrophotometer |
Absorbance/Transmission (liquid sample) Reflectance (Solid sample) |
- |
250 PS
350 PS |
400 PS
600 PS |
700 PS 1000 PS |
6. |
FTIR Spectroscopy |
Spectral analysis for liquid and solid samples using Fourier Transform IR principle |
- |
75 PS |
150 PS |
250 PS |
7. |
UV visible spectrophotometer |
Light transmission studies |
- |
25 PS |
50 PS |
100 PS |
8. |
Bomb Calorimeter |
Calorific value measurement by thermal analysis |
- |
300 PS |
600 PS |
1000 PS |
9. |
Moisture Analyzer |
Measurement of moisture from ppm to percentage for liquid & solid samples |
- |
500 PS |
1000 PS |
2000 PS |
* S- Sample, PS- Per Sample, PHr- Per Hour
Note:
1. All analysis is made in normal specification ranges. Special request can be executed only if it is mentioned in the special instruction column of application form of the instrument.
2. TGA, DSC instruments are operated on hour basis. Extra charges Rs.100/-, 200/- 300/- for Educational Institute, National Laboratory, Industry will be applicable respectively.
3. Service tax @12.36% is applicable extra and it is 5% for Educational Institution.
4. Samples will be analyzed once in a week and it depends on accumulation of sample at DEE.
5. Student/Employee is requested to see the make, model, specification and working condition of the instruments before apply.
6. Student/Employee is requested to submit the nature of the sample preparation along with application form.
7. Student/Employee is requested to bring clean sample of minimum quantity with proper order and labeling.
8. Application form should be submitted offline along with DD in favor of The Director, NIT Trichy payable at Tiruchirappalli to Head DEE. The sample will be processed subject to submission & approval of payment by concerned.
9. Complaints regarding the measurements can be given to Head, DEE.
10. Any special help other than routine measurements will be treated only as consultancy service. Servicing and training for both operation and maintenance of analytical instruments will also be undertaken on specific requirements on request.
11. For further details please contact Head, DEE, NITT.